logik lvd7w18 problems

The Logik LVD7W18 tumble dryer is a commonly used appliance in many households. However, users sometimes encounter problems, notably with the appliance’s fuse blowing frequently. This article explores the issue and provides solutions to help users effectively troubleshoot and fix the problem.

Problem: Frequent Blowing of the Tumble Dryer’s 3amp Plug Fuse

A key issue faced by users of the Logik LVD7W18 tumble dryer is the blowing of the 3amp plug fuse, particularly when the start button is pressed. Despite checks on the thermal fuse, thermostat, and element showing no issues, the problem persists.

Potential Causes and Solutions

  1. Inadequate Fuse Amperage: The most apparent cause of the fuse blowing is that a 3amp fuse may be too small for a tumble dryer, which typically requires a 13amp fuse.
    • Solution: Replace the 3amp fuse with a 13amp fuse, as this is more appropriate for the power requirements of a tumble dryer.
  2. Faulty Heating Element: Given that there was a recall for faulty heaters in certain models, the problem could be related to the heating element.
    • Solution: Check if the model is part of a product recall for faulty heaters. If it is, follow up with the manufacturer for a replacement or repair.
  3. Faulty Electrical Components: The issue might also be due to other electrical components within the dryer.
    • Solution: Gradually reconnecting electrical components one at a time to identify which causes the fuse to blow can isolate the problem. This should be done cautiously and preferably by someone with electrical knowledge.

Checking the Recall Status

  • Contact the Manufacturer: If there’s a recall on the model, contact the manufacturer for further instructions. They may offer a repair, replacement, or a discounted rate for a different model.

Additional Considerations

  1. Electrical Safety: Always ensure that any replacement or troubleshooting is done safely, with the power turned off.
  2. Use Correct Fuse Rating: The fuse rating should be appropriate for the appliance’s power rating. The calculation (2000W / 240V + 10%) indicates that a minimum of a 9.1amp fuse is required, so a 13amp fuse is more suitable than a 3amp.
  3. RCD Protection: Confirm that the socket used for the dryer is protected by a Residual Current Device (RCD) for added safety.
  4. Professional Assistance: If unsure about any steps, especially when dealing with electrical components, seek help from a qualified technician.

Conclusion

Frequent blowing of the fuse in a Logik LVD7W18 tumble dryer can often be resolved by replacing the fuse with one of a higher amperage. Users should also check if their model is part of a product recall and follow up accordingly. Taking appropriate safety precautions and consulting professionals when necessary can help ensure a safe and effective resolution to the problem. Regular maintenance and awareness of the appliance’s electrical requirements are key to preventing future issues.